Monday, 8 August 2022

Sony KV-SW21M50 (WEGA) Protect !

Sony KV-SW21M50 device ( WEGA To protect it , yaitu saat of start TV bisa nyala normal ekidit lalu mati, gambar maskup pelan arah vertical menjadi standby!
After Ubek 2 half Jam Akshirnya met Jug!
It appears that the clock is flashing, the RGB amplifier circuit is not working, the 200V is not working!
Berikutnya sy mengut elco filter 200v Decat flyback ( 8-598-858-00 ), it turned out to be normal.

No ... if you meet him again, the solution is:
Going to Sony type INI, 200V RGB amplifier circuit is not directly connected but still passes 2 combinations of NPN and PNP transistors controlled by main IC, like T7DAH/ !
Short base manifold can be used with Q8010 (NPN) and Q8009 (PNP) bases.
With Q8009 and Q8009, along with TR's A1013, you can use normal RGB... well!

Attention ...
Protect your Sony TV, use RGB with CRT/Tabung! Karen Kalau Dileps Kerja Messin Masih Separti Defense Court is normal....!!!!

No comments:

Post a Comment

Note: only a member of this blog may post a comment.

Kerusakan2 Tv. (Bag. 13)

1. BINTANG EMAS-CA14A62 Gambar halus, offset PIF tetap: lihat Z201 (CF5.5 MHz). * Tes: Sentuh Basis Q202, gambar bagus. 2.SHARP-51R200 H...